SWH-200IRA
- Indoor unit
- No cross contamination potential, refrigerant coil is wrapped around the tank and insulated
- High efficiency
OUTDOOR UNIT | - | - | - |
Capacity | Heating | 3500 | W |
Rated Power Input | Cooling / Heating | 0,85 | kW |
COP | - | 4,10 | W / W |
COP DHW | - | 3,17 | W / W |
Energy class | - | A | - |
Water heating energy efficient | - | 129 % | - |
Annual electricity consumption | (average climate conditions) | 795 | kWh |
Power Input | - | 1,5 + 1,5 (Electric heater) | kW |
Output Water Temperature | - | Default 55, 35 ~ 55 | °C |
Power Supply | - | 220 - 240 / 1 / 50 | V / Ph / Hz |
Insulation level | - | I | - |
Protection of ingression | - | IPX4 | - |
Refrigerant / Charge / Eq. CO2 | - | R410A / 1,40 / 2,92 | type / kg / t |
Outline Dimensions | w x d x h | 842 x 320 x 591 | mm |
Package Dimensions | w x d x h | 941 x 371 x 660 | mm |
Net Weight | - | 38,5 | kg |
Gross Weight | - | 44,5 | kg |
Sound power level | Exterier | 63 | dB(A) |
Operating Temperature | - | -25 ~ 45 | °C |
INDOOR UNIT | - | - | - |
Storage Size | - | 185 | l |
Electric Heater | Power Supply | 220–240 / 1 / 50 | V / Ph / Hz |
Electric Heater | Capacity | 1,5 | kW |
Dimension (w x h x d) | Indoor Unit | 545 x 545 x 1919 | mm |
Net / Gross Weight | Indoor Unit | 52 / - | kg |
Refrigerant Liquid Pipe | Diameter | 1/4 / 6 | inch / mm |
Refrigerant Gas Pipe | Diameter | 3/8 / 9,5 | inch / mm |
Water Pipe Inlet / Outlet | Diameter | - / DN15 | mm (inch) |
Tank material | - | stainless steel | - |
Notes |
The specification of products is subject to change based further development of the units by the producer and can be changed without prior notice. Refer to rating label. Data are based on following conditions:
The devices contains fluorinated greenhouse gases covered by the Kyoto Protocol. Noise is tested in the semi-anechoic room, so it should be slightly higher in the actual Operation due to environmental change. Power input is tested under standard condition. |
indoor unit
outdoor unit