Wall mounted units archive

ASH-12AIE

  • Energy class A / A
  • Cooling capacity 3,5kW
  • Heating capacity 3,8kW
  • 3-year warranty
  • DC Inverter technology
  • Standart filters - Catechin and Carbon
  • Dual side water outlet
  • Comfortable sleep mode
  • Heating until - 7°C
  • High speed digital signal processor
  • Compact design
Capacity Cooling / Heating 3,5 (0,6 - 4,0) / 3,8 (0,6 - 5,1) kW
Power Supply Into Outdoor Unit 220 - 240 / 1 / 50 V / Ph / Hz
Power Input Cooling / Heating 1,15 / 1,1 kW
Rated Power Input Cooling / Heating 1,55 / 1,65 kW
Power Current Cooling / Heating 5,1 / 4,9 A
SEER / SCOP - 5,6 / 3,8 W / W
Energy Class Cooling / Heating A / A -
Air Flow Indoor Unit 680 / 560 / 410 / 300 m3 / h
Air Flow Outdoor Unit 1800 m3 / h
Sound Pressure Level at 1 m Indoor Unit 42 / 39 / 31 / 25 dB(A)
Sound Pressure Level at 1 m Outdoor Unit 53 dB(A)
Dehumidifying Volume - 1,4 l / h
Refrigerant / Charge / Eq. CO2 - R410A / 1,0 type / kg / t
Refrigerant Liquid Pipe Diameter 1/4 / 6,4 inch / mm
Refrigerant Gas Pipe Diameter 3/8 / 9,5 inch / mm
Max pipe length without additional refrigerant - 5 m
Min. / Max. Pipe Length - 3 / 20 m
Max. Elevation - 10 m
Additional Refrigerant - 20 g / m
Dimension (w x h x d) Indoor Unit 770 x 283 x 201 mm
Dimension (w x h x d) Outdoor Unit 776 x 540 x 320 mm
Net / Gross Weight Indoor Unit 9,0 / - kg
Net / Gross Weight Outdoor Unit 30,0 / - kg
Operating Temperature Range Cooling 18 ~ 43 °C
Operating Temperature Range Heating - 7 ~ 24 °C
Notes

The specification of products is subject to change based further development of the units by the producer and can be changed without prior notice. Refer to rating label. Data are based on following conditions:

  • Length of connection pipe: 5m
  • Cooling condition: indoor temperature 27°C DB / 19°C WB, outdoor temperature 35°C DB / 24°C WB
  • Heating condition: indoor temperature 20°C DB / 15°C WB, outdoor temperature 7°C DB / 6°C WB
  • Refrigerant: R410A (50% HFC-32, 50% HFC-125) with GWP (Global Warming Potential) 2088

The devices contains fluorinated greenhouse gases covered by the Kyoto Protocol. Noise is tested in the semi-anechoic room, so it should be slightly higher in the actual Operation due to environmental change. Power input is tested under standard condition.

Our Clients And Business Partners

Our strength is quality products with reasonable price setting. We have very wide product range, with very good stock availability whole year round. We put emphasis on aftersales service, spare parts availability and technical support, also we provide technical trainings. With our partners we create long term, mutually benefitial business cooperation.