Chillers archive

SCV-300EA

  • Modular design concept
  • Combination of up to 16 modules
  • All units can be connected together with a three-core wired controller in series type
  • On PCB you can remotely control: ON/OFF, heating/cooling, alarm
  • High efficient full DC inverter compressor
  • Economical operation
  • Flexible pipe connection and installation
  • Wired controller KJRM-120H in standard
Power supply - 380-415/3/50 V/Ph/Hz
Cooling 1 Capacity 27 kW
Cooling 1 Input 10,8 kW
Cooling 1 EER 2,50 -
Heating 1 Capacity 31 kW
Heating 1 Input 10,5 kW
Heating 1 COP 2,95 -
Max. running current - 18,0 A
Compressor Type DC invertor rotary -
Compressor Quantity 1 -
Air side heat exchanger Type Finned tube -
Air side heat exchanger Quantity of fan motor 1 -
Air side heat exchanger Air flow 12500 m3/h
Water side heat exchanger Type Plate -
Water side heat exchanger Water pressure drop 60 kPa
Water side heat exchanger Volume 2,44 l
Water side heat exchanger Water flow volume 5,0 m3/h
Refrigerant Type R410A -
Refrigerant Charge volume 10,5 / 21,9 kg / t eq. CO2
Refrigerant Throttle type EXV + Capillary -
Sound Pressure Level at 1 m - 66 dB(A)
Unit net dimension (wxhxd) 1000x1175x1870 mm
Packing dimension (wxhxd) 1035x1225x1910 mm
Net / Gross weight - 300 / 310 kg
Pipe Connections Water Inlet / Outlet DN40 mm
Controller - Wired -
Ambient temperature range Cooling -10~43 °C
Ambient temperature range Heating -15~30 °C
Water outlet temperature range Cooling 5~20 °C
Water outlet temperature range Heating 25~55 °C
Package volume - 2,422 m3
Notes

The specification of products is subject to change based further development of the units by the producer and can be changed without prior notice. Refer to rating label. Data are based on following conditions:

  • Cooling 1: Chilled water inlet/outlet temperature: 12/7°C, outdoor ambient temperature 35°C DB.
  • Heating 1: Warm water inlet/outlet temperature: 40/45°C, outdoor ambient temperature 7°C DB/6°C WB.
  • Sound pressure level: 1m far from unit in open field.
  • Refrigerant: R410A (50% HFC-32, 50% HFC-125) with GWP (Global Warming Potential) 2088.

The devices contains fluorinated greenhouse gases covered by the Kyoto Protocol. Noise is tested in the semi-anechoic room, so it should be slightly higher in the actual Operation due to environmental change. Power input is tested under standard condition.

Our Clients And Business Partners

Our strength is quality products with reasonable price setting. We have very wide product range, with very good stock availability whole year round. We put emphasis on aftersales service, spare parts availability and technical support, also we provide technical trainings. With our partners we create long term, mutually benefitial business cooperation.