FLOOR-CEILING UNITS

SDV4-36FAF

  • DC fan motor
  • Cooling capacity 3,6kW
  • Heating capacity 4,0kW
  • 3 speed of fan (36 - 40dB)
  • Remote controller RM02
  • Outdoor unit is separate product
Capacity Cooling 3,6 kW
Capacity Heating 4,0 kW
Power Supply - 220–240 / 1 / 50 V / Ph / Hz
Rated Power - 23 W
Performance Air Flow Volume 550 / 480 / 420 m3 / h
Performance Sound Pressure Level at 1 m 40 / 38 / 36 dB(A)
Refrigerant - R410A type
Net Dimension w x h x d 990 x 660 x 203 mm
Packing Dimensions w x h x d 1089 x 744 x 296 mm
Net Weight - 25,0 kg
Gross Weight - 31,0 kg
Pipe Diameter Liquid Side 6,4 mm
Pipe Diameter Gas Side 12,7 mm
Pipe Diameter Drainage Pipe 25 mm
Package volume - 0,240 m3
Notes

The pictures of units and accessories are illustrative only. Technical specifications of the products are subject of change based on further development of the units by the producer and may be changed without prior notice. If the ask of the output power is greater than the nominal value of the outdoor unit (or a combination of outdoor units, hereinafter the outdoor unit) the output power may be limited to a maximum of 100% of the nominal capacity of the outdoor unit. During the overall performance requirements of less than 10% of the nominal power can cause overcooling of the room operated by the indoor unit. The outdoor unit in order to protect the compressor can reject to start until the demand of power is in balance with potential risks.
The device contains fluorinated greenhouse gases covered by the Kyoto Protocol. Refrigerant: R410A (50% HFC-32, 50% HFC-125) with GWP (Global Warming Potential) 2088.

CONDITIONS UNDER WHICH HAS BEEN PERFORMED MEASUREMENTS OF TECHNICAL PARAMETERS:
OUTDOOR UNITS

  1.  Capacities are based on the following conditions: Cooling: Indoor temperature 27°C DB / 19°C WB; Outdoor temperature 35°C DB / 24°C WB. Heating: Indoor temperature 20°C DB / 15°C WB; Outdoor temperature 7°C DB / 6°C WB. Piping length: Interconnecting piping length is 7.5m, level difference is 0m.
  2. Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m. When the total equivalent liquid length is more than 90m, please refer to technical manual to choose the connection piping diameter.
  3. Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.
  4. The above data may be changed without notice for further improvement on quality and performance.

INDOOR UNITS

  1. Nominal cooling capacities are based on the following conditions: return air temperature: 27°C DB / 19°C WB, outdoor temperature: 35°C DB, equivalent ref. piping: 8m (horizontal).
  2. Nominal heating capacities are based on the following conditions: return air temperature: 20°CDB, outdoor temperature: 7°C DB / 6°C WB, equivalent ref. piping: 8m (horizontal).
  3. Sound values are measured at a position 1.4m in front of the unit.

Our Clients And Business Partners

Our strength is quality products with reasonable price setting. We have very wide product range, with very good stock availability whole year round. We put emphasis on aftersales service, spare parts availability and technical support, also we provide technical trainings. With our partners we create long term, mutually benefitial business cooperation.