WATER HEATERS

SWH-35ERA2 + SWH-200DE

Split Water Heater

  • Set consisting of the outdoor unit and enamelled DHW tank
  • High efficiency
  • No risk of water contamination, the refrigerant coil is in an insulated container around the tank.
OUTDOOR UNIT - SWH-35ERA2 -
Capacity Heating 3,5 kW
Power Input - 0,83 kW
COP - 4,10 W
COP DHW - 3,10 W
Energy class - A+ -
Water heating energy efficient - 130 % -
Annual electricity consumption (average climate conditions) 795 kWh
Rated Power Input - 2,0 + 1,5 (Electric heater) kW
Output Water Temperature - Default 55, 35 ~ 55 °C
Power Supply - 220 - 240 / 1 / 50 V / Ph / Hz
Insulation level - I -
Protection of ingression - IPX4 -
Refrigerant / Charge / Eq. CO2 - R410A / 1,40 / 2,92 type / kg / t
Outline Dimensions w x d x h 842 x 320 x 591 mm
Package Dimensions w x d x h 941 x 371 x 660 mm
Net Weight - 38,5 kg
Gross Weight - 44,5 kg
Sound Pressure Level at 1 m - 49 dB(A)
Sound power level - 63 dB(A)
Operating range - -25~45 °C
Standard Pipe Length - 10 m
Max. Pipe Length - 20 m
Max. Elevation - 5 m
Additional Refrigerant (Over 10 m Pipe Length) 22 g / m
INDOOR UNIT - SWH-200DE -
Tank Volume - 185 l
Electric Heater Power Supply 220–240 / 1 / 50 V / Ph / Hz
Electric Heater Capacity 1,5 kW
Dimension (w x h x d) Indoor Unit 462 × 2000 × 462 mm
Net / Gross Weight Indoor Unit 72,5 / 83,0 kg
Pipe Diameter Liquid Side 6,0 mm
Pipe Diameter Gas Side 9,52 mm
Water Pipe Inlet / Outlet Diameter 3/4" / DN20 mm (inch)
Tank material - enamel -
Notes

Input power, COP: Values measured under the following conditions: Outdoor temperature: 20 °C DB / 15 °C WB; Water tank temperature (start/end): 15 °C / 55 °C. COP DHW, Energy class: Values measured under the following conditions: air temperature 7 °C, inlet water temperature 10 °C. According to EN 16147-2011, (EU) No 814/2013. Sound power level: Values measured according to EN 12102-2008.

The technical specification of the products may differ from the stated values according to product development by the manufacturer. Please refer to the parameters on the unit nameplate. The sound pressure level is tested in an anechoic chamber, the actual values may be affected by local conditions. The equipment contains fluorinated greenhouse gases covered by the Kyoto Protocol – refrigerant R410A (50% HFC-32, 50% HFC-125) with GWP 2088.

Our Clients And Business Partners

Our strength is quality products with reasonable price setting. We have very wide product range, with very good stock availability whole year round. We put emphasis on aftersales service, spare parts availability and technical support, also we provide technical trainings. With our partners we create long term, mutually benefitial business cooperation.

Your choices regarding the setting of cookies on this website: Read our cookie policy