ASH-09BIF
- Year 2017–2018, FOCUS series
- Energy class A++ / A+
- Cooling capacity 2,6kW
- Heating capacity 2,8kW
- 3-year warranty
- New ecofriendly refrigerant R32
- Standard WiFi control (Smart application)
- Standard filters - catechin SAF-OPWA1 and active carbon filter SAF-OPWA1
- Cold plasma generator
- Optional wired controller SWC-02 with weekly timer
Capacity | Cooling / Heating | 2,6 / 2,8 | kW |
Power Supply | Into Outdoor Unit | 220 - 240 / 1 / 50 | V / Ph / Hz |
Power Input | Cooling / Heating | 0,805 / 0,755 | kW |
Rated Power Input | Cooling / Heating | 1,5 | kW |
Power Current | Cooling / Heating | 3,9 / 3,4 | A |
Rated Power Current | Cooling / Heating | 6,3 | A |
SEER / SCOP | - | 6,1 / 4,0 | W / W |
Energy Class | Cooling / Heating | A++ / A+ | - |
Air Flow | Indoor Unit | 560 / 490 / 430 / 330 | m3 / h |
Air Flow | Outdoor Unit | 1600 | m3 / h |
Sound Pressure Level at 1 m | Indoor Unit | 39 / 36 / 32 / 28 | dB(A) |
Sound Pressure Level at 1 m | Outdoor Unit | 52 | dB(A) |
Dehumidifying Volume | - | 0,8 | l / h |
Refrigerant / Charge / Eq. CO2 | - | R32 / 0,6 / 0,41 | type / kg / t |
Refrigerant Liquid Pipe | Diameter | 1/4 / 6 | inch / mm |
Refrigerant Gas Pipe | Diameter | 3/8 / 9,5 | inch / mm |
Max pipe length without additional refrigerant | - | 5 | m |
Min. / Max. Pipe Length | - | 3 / 15 | m |
Max. Elevation | - | 10 | m |
Additional Refrigerant | - | 20 | g / m |
Dimension (w x h x d) | Indoor Unit | 790 x 275 x 200 | mm |
Dimension (w x h x d) | Outdoor Unit | 776 x 540 x 320 | mm |
Package (w x h x d) | Indoor Unit | 866 x 271 x 367 | mm |
Package (w x h x d) | Outdoor Unit | 823 x 358 x 595 | mm |
Net / Gross Weight | Indoor Unit | 9,0 / 11,0 | kg |
Net / Gross Weight | Outdoor Unit | 29,5 / 32,0 | kg |
Set Temperature range | - | 16 ~ 30 | °C |
Operating Temperature Range | Cooling | -15 ~ 43 | °C |
Operating Temperature Range | Heating | - 22 ~ 24 | °C |
Spacing of holes on consoles (OU) | wight x depth | 510 x 286 | mm |
Notes |
The specification of products is subject to change based further development of the units by the producer and can be changed without prior notice. Refer to rating label. Data are based on following conditions:
The devices contains fluorinated greenhouse gases covered by the Kyoto Protocol. Noise is tested in the semi-anechoic room, so it should be slightly higher in the actual Operation due to environmental change. Power input is tested under standard condition. |
ACTIVE CARBON FILTER SAF-OPWA1
BIOLOGICAL ANTI-BACTERIA FILTER SAF-OPWB1