KEYON SERIES

SIH + SOH-24BIK

  • Energy class A++ / A+
  • Cooling capacity 6,2 kW
  • Heating capacity 6,5 kW
  • Dual side water outlet
  • Hidden display
  • Horizontal guide louver swing
  • Function „I FEEL“
  • 8 °C heating
  • Cold plasma generator
  • WiFi module
  • Remote controller YAA1FB6 (WiFi)
Capacity Cooling / Heating 6,2 (1,8–6,4) / 6,5 (1,6–6,6) kW
Power Supply Into Outdoor Unit 220 - 240 / 1 / 50 V / Ph / Hz
Power Input Cooling / Heating 1,77 / 1,65 kW
Rated Power Input Cooling / Heating 2,2 kW
Power Current Cooling / Heating 7,9 / 7,3 A
Rated Power Current Cooling / Heating 10,0 A
Energy class Cooling / Heating (A, W, C) * A++ / (A+, A+++, -) -
Pdesign Cooling / Heating 6,2 / 4,7 kW
SEER / SCOP - 6,8 / 4,0 W / W
Annual Electricity Consumption Cooling / Heating 319 / 1645 kWh
Air Flow Indoor Unit 1100 / 950 / 750 / 650 m3 / h
Air Flow Outdoor Unit 2800 m3 / h
Sound Pressure Level at 1 m Indoor Unit 48 / 44 / 40 / 35 dB(A)
Sound Pressure Level at 1 m Outdoor Unit 58 dB(A)
Sound Power Level Indoor unit 61 / 58 / 53 / 49 dB(A)
Sound Power Level Outdoor unit 67 dB(A)
Dehumidifying Volume - 1,8 l / h
Refrigerant / Charge / Eq. CO2 - R32 / 1,30 / 0,88 type / kg / t
Additional Refrigerant - 16 g / m
Refrigerant Liquid Pipe Diameter 1/4 / 6 inch / mm
Refrigerant Gas Pipe Diameter 1/2 / 12 inch / mm
Max pipe length without additional refrigerant - 5 m
Min. / Max. Pipe Length - 3 / 25 m
Max. Elevation - 10 m
Dimension (w x h x d) Indoor Unit 1081 x 325 x 248 mm
Dimension (w x h x d) Outdoor Unit 873 x 555 x 376 mm
Package (w x h x d) Indoor Unit 1137 x 407 x 334 mm
Package (w x h x d) Outdoor Unit 951 x 620 x 431 mm
Net / Gross Weight Indoor Unit 16,5 / 19,5 kg
Net / Gross Weight Outdoor Unit 36,5 / 39,5 kg
Set Temperature range - 16 ~ 30 °C
Operating Temperature Range Cooling -15 ~ 43 °C
Operating Temperature Range Heating - 15 ~ 24 °C
Notes

The technical specification of the products may differ from the stated values according to product development by the manufacturer. Please refer to the parameters on the unit nameplate.
R32 (one-component HFC refrigerant). GWP value of refrigerant used: 675
This equipment contains fluorinated greenhouse gases covered by the Kyoto Protocol.

* A, W, C – Values for different climates. A = Average; W = Warmer; C = Colder

Our Clients And Business Partners

Our strength is quality products with reasonable price setting. We have very wide product range, with very good stock availability whole year round. We put emphasis on aftersales service, spare parts availability and technical support, also we provide technical trainings. With our partners we create long term, mutually benefitial business cooperation.