  • Energy class A++ / A+
  • Cooling capacity 2,7 kW
  • Heating capacity 3,0 kW
  • Dual side water outlet
  • Hidden display
  • 7 speeds of fan
  • Horizontal and vertical guide louver swing
  • Function „I FEEL“
  • 8 °C heating
  • Standard filters – Catechin filter SAF-OPWC4 and silver ion filter SAF-OPWS4
  • Cold plasma generator
  • WiFi module
  • Dry ON / OFF contact
  • Crankcase heater, chassis heater
  • Remote controller YAC1FB9 (WiFi)
  • Available in 4 color variations – black (SIH-XXBITB), silver (SIH-XXBITS), champagne (SIH-XXBITC), white (SIH-XXBITW)
Capacity Cooling / Heating 2,7 (0,8–3,8) / 3,0 (0,9–4,2) kW
Power Supply Into Outdoor Unit 220 - 240 / 1 / 50 V / Ph / Hz
Power Input Cooling / Heating 0,70 / 0,70 kW
Rated Power Input Cooling / Heating 1,4 kW
Power Current Cooling / Heating 3,1 / 3,2 A
Rated Power Current Cooling / Heating 6,2 A
Energy class Cooling / Heating (A, W, C) * A++ / (A+, A+++, A) -
Pdesign Cooling / Heating 2,7 / 2,7 kW
SEER / SCOP - 7,5 / 4,2 W / W
Annual Electricity Consumption Cooling / Heating 126 / 900 kWh
Air Flow Indoor Unit 610 / 570 / 540 / 470 / 440 / 420 / 390 m3 / h
Air Flow Outdoor Unit 1950 m3 / h
Sound Pressure Level at 1 m Indoor Unit 38 / 36 / 34 / 31 / 29 / 27 / 25 dB(A)
Sound Pressure Level at 1 m Outdoor Unit 50 dB(A)
Sound Power Level Indoor unit 56 / 48 / 46 / 43 / 41 / 39 / 37 dB(A)
Sound Power Level Outdoor unit 61 dB(A)
Dehumidifying Volume - 0,8 l / h
Refrigerant / Charge / Eq. CO2 - R32 / 0,53 / 0,36 type / kg / t
Additional Refrigerant - 16 g / m
Refrigerant Liquid Pipe Diameter 1/4 / 6 inch / mm
Refrigerant Gas Pipe Diameter 3/8 / 9,5 inch / mm
Max pipe length without additional refrigerant - 5 m
Min. / Max. Pipe Length - 3 / 15 m
Max. Elevation - 10 m
Dimension (w x h x d) Indoor Unit 889 × 294 × 212 mm
Dimension (w x h x d) Outdoor Unit 732 × 555 × 330 mm
Package (w x h x d) Indoor Unit 940 × 365 × 284 mm
Package (w x h x d) Outdoor Unit 794 × 615 × 376 mm
Net / Gross Weight Indoor Unit 11,0 / 13,0 kg
Net / Gross Weight Outdoor Unit 23,5 / 26,0 kg
Set Temperature range - 16 ~ 30 °C
Operating Temperature Range Cooling -15 ~ 50 °C
Operating Temperature Range Heating - 25 ~ 30 °C
Notes

The technical specification of the products may differ from the stated values according to product development by the manufacturer. Please refer to the parameters on the unit nameplate.
R32 (one-component HFC refrigerant). GWP value of refrigerant used: 675
This equipment contains fluorinated greenhouse gases covered by the Kyoto Protocol.

* A, W, C – Values for different climates. A = Average; W = Warmer; C = Colder

Our Clients And Business Partners

Our strength is quality products with reasonable price setting. We have very wide product range, with very good stock availability whole year round. We put emphasis on aftersales service, spare parts availability and technical support, also we provide technical trainings. With our partners we create long term, mutually benefitial business cooperation.