GSH-90ERAD
- High efficiency and energy saving
- Comfortable
- Intelligent control
- PFC control technology
- BLDC motor control technology
- 5 years warranty
Power Supply | - | 220 - 240 / 1 / 50 | V / Ph / Hz |
A7 / W35 | Heating Capacity | 8,53 | kW |
A7 / W35 | Power Input | 1,99 | kW |
A7 / W35 | COP | 4,27 | - |
A2 / W35 | Heating Capacity | 6,88 | kW |
A2 / W35 | Power Input | 2,02 | kW |
A2 / W35 | COP | 3,41 | - |
A-7 / W35 | Heating Capacity | 5,20 | kW |
A-7 / W35 | Power Input | 2,36 | kW |
A-7 / W35 | COP | 2,20 | - |
Sound Pressure Level at 1 m | - | 54 | dB(A) |
Energy class | Heating (55°C / 35°C) | A+ / A++ | - |
Energy class | Water heating | A | - |
Refrigerant / Charge / Eq. CO2 | - | R410A / 3,5 / 7,3 | type / kg / t |
Max pipe length without additional refrigerant | - | 5 | m |
Min. / Max. Pipe Length | - | 3 / 30 | m |
Max. Elevation | - | 15 | m |
Additional Refrigerant | - | 50 | g / m |
Sanitary Water Temperature | - | 40 ~ 80 | °C |
Refrigerant Liquid Pipe | Diameter | 3/8 / 9,5 | inch / mm |
Refrigerant Gas Pipe | Diameter | 5/8 / 16 | inch / mm |
Outline Dimensions | w x d x h | 980 x 427 x 788 | mm |
Net Weight | - | 85 | kg |
Operating range | - | -20~45 | °C |
Notes |
The specification of products is subject to change based further development of the units by the producer and can be changed without prior notice. Refer to rating label. Data are based on following conditions:
The devices contains fluorinated greenhouse gases covered by the Kyoto Protocol. Noise is tested in the semi-anechoic room, so it should be slightly higher in the actual Operation due to environmental change. Power input is tested under standard condition. |