SWH-35ERA2 + SWH-200IRA2
Split Water Heater
- Set consisting of the outdoor unit and enamelled DHW tank
- High efficiency
- No risk of water contamination, the refrigerant coil is in an insulated container around the tank.
OUTDOOR UNIT | - | SWH-35ERA2 | - |
Capacity | Heating | 3,5 | kW |
Power Input | - | 0,83 | kW |
COP | - | 4,10 | W |
COP DHW | - | 3,10 | W |
Energy class | - | A+ | - |
Water heating energy efficient | - | 130 % | - |
Annual electricity consumption | (average climate conditions) | 795 | kWh |
Rated Power Input | - | 2,0 + 1,5 (Electric heater) | kW |
Output Water Temperature | - | Default 55, 35 ~ 55 | °C |
Power Supply | - | 220 - 240 / 1 / 50 | V / Ph / Hz |
Insulation level | - | I | - |
Protection of ingression | - | IPX4 | - |
Refrigerant / Charge / Eq. CO2 | - | R410A / 1,40 / 2,92 | type / kg / t |
Outline Dimensions | w x d x h | 842 x 320 x 591 | mm |
Package Dimensions | w x d x h | 941 x 371 x 660 | mm |
Net Weight | - | 38,5 | kg |
Gross Weight | - | 44,5 | kg |
Sound Pressure Level at 1 m | - | 49 | dB(A) |
Sound power level | - | 63 | dB(A) |
Operating range | - | -25~45 | °C |
Standard Pipe Length | - | 10 | m |
Max. Pipe Length | - | 20 | m |
Max. Elevation | - | 5 | m |
Additional Refrigerant | (Over 10 m Pipe Length) | 22 | g / m |
INDOOR UNIT | - | SWH-200IRA2 | - |
Tank Volume | - | 185 | l |
Electric Heater | Power Supply | 220–240 / 1 / 50 | V / Ph / Hz |
Electric Heater | Capacity | 1,5 | kW |
Dimension (w x h x d) | Indoor Unit | 462 x 462 x 1944 | mm |
Package (w x h x d) | Indoor Unit | 583 x 583 x 2045 | mm |
Net / Gross Weight | Indoor Unit | 75,0 / 88,0 | kg |
Pipe Diameter | Liquid Side | 6,0 | mm |
Pipe Diameter | Gas Side | 9,5 | mm |
Water Pipe Inlet / Outlet | Diameter | - / DN15 | mm (inch) |
Tank material | - | enamel | - |
Notes |
Input power, COP: Values measured under the following conditions: Outdoor temperature: 20 °C DB / 15 °C WB; Water tank temperature (start/end): 15 °C / 55 °C. COP DHW, Energy class: Values measured under the following conditions: air temperature 7 °C, inlet water temperature 10 °C. According to EN 16147-2011, (EU) No 814/2013. Sound power level: Values measured according to EN 12102-2008. The technical specification of the products may differ from the stated values according to product development by the manufacturer. Please refer to the parameters on the unit nameplate. The sound pressure level is tested in an anechoic chamber, the actual values may be affected by local conditions. The equipment contains fluorinated greenhouse gases covered by the Kyoto Protocol – refrigerant R410A (50% HFC-32, 50% HFC-125) with GWP 2088. |