DUCT, 3 ROWS, 2 PIPES

SF2-1000D3

  • Indoor unit - water
  • High efficient heat exchanger
  • Longer V shape drainage pan
  • DC brushless fan motor
  • Support central controller SCM-30
  • Support MODBUS RTU
  • Option wired controller SWC-61
  • Option SF2-DTK supports control via 230V – high, medium, low fan speed
  • Option SF2-EC supports fan control via 0-10V (requires SF2-DTK)
  • Recommend to connect external 3 or 2 way valve NC 230V
Power System Type 220 - 240 / 1 / 50 V / Ph / Hz
Air flow (H/M/L) 1665 / 1204 / 740 m3/h
Air flow (H/M/L) 979 / 708 / 435 CFM
Standard external static pressure - 12Pa (Default); 30/50Pa can be set through dial switch on PCB Pa
Cooling Capacity (H/M/L) 9,05 / 7,10 / 4,97 kW
Cooling Water flow rate 1,58 / 1,26 / 0,88 l/h
Cooling Water pressure drop 32,00 / 22,01 / 11,71 kPa
Heating Capacity (H/M/L) 11,00 / 8,02 / 5,41 kW
Heating Water flow rate 1,78 / 1,36 / 0,92 l/h
Heating Water pressure drop 33,0 / 21,6 / 10,9 kPa
Power System Input 119,0 W
Sound Pressure Level at 1 m 12Pa (H/M/L) 50/43/36 dB(A)
Fan motor Type DC motor -
Fan motor Quantity 1 -
Fan Type Centrifugal, forward-curved blades -
Fan Quantity 3 -
Coil Row 3 -
Coil Max. working pressure 1,6 MPa
Coil Diameter 7,0 mm
Outline Dimensions w x d x h 1368 x 243 x 482 mm
Package Dimensions w x d x h 1438 x 270 x 520 mm
Net Weight - 27,7 kg
Gross Weight - 30,7 kg
Connection Pipe Size Water Inlet / Outlet RC3/4 inch
Connection pipe size Condenset drain ZG3/4 inch
Notes
  • H: High fan speed, M: Medium fan speed, L: Low fan speed.
  • Cooling mode: entering air temperature 27°C DB/19°C WB, entering/leaving water temperature 7°C /12°C, with air return plenum and filter.
  • Heating mode: entering air temperature 20°C DB, entering/leaving water teperaure 45/40°C, with air return plenum and filter.
  • Sound pressure level is tested in the semi-anechoic room with background noise is 17,5dB (A), when the unit is without accessories and running in dry condition, at 1m below & 1m front the vertical center line of the unit with 1m outlet duct.
  •  Air flow is tested under dry condition, 20°C DB, with air return plenum and filter.
  • Left and right unit can be changed in the field, but cooling should be multiplied with correction factor 0,9.

The specification of products is subject to change based on further development of the units by the producer and can be changed without prior notice. Refer to rating label.

WIRE CONTROLLER SWC-61

CENTRAL CONTROLLER SCM-30

Our Clients And Business Partners

Our strength is quality products with reasonable price setting. We have very wide product range, with very good stock availability whole year round. We put emphasis on aftersales service, spare parts availability and technical support, also we provide technical trainings. With our partners we create long term, mutually benefitial business cooperation.

Your choices regarding the setting of cookies on this website: Read our cookie policy