SMHM-100B/3
- Possibility of control via internet with ILetComfort application
- High efficiency
- Circulatory pump with self-regulation of speed
- Integrated expansion vessel and safety valve
- Silent mode
- The outlet water temperature from 25 °C to 65 °C
- Built-in electric cartridge with 3 or 9 kW capacity
- Keymark Certification
Capacity | Heating | 10,0 | kW |
Capacity | Cooling | 9,9 | kW |
Power Input | Heating | 2,02 | kW |
Power Input | Cooling | 2,18 | kW |
COP | Heating | 4,95 | - |
EER | Cooling | 4,55 | - |
Energy class | Heating (55°C / 35°C) | A++ / A+++ | - |
SCOP | Heating (55 °C / 35 °C) | 3,47 / 5,20 | - |
Power Supply | - | 220 - 240 / 1 / 50 | V / Ph / Hz |
Rated Power Input | - | 3,43 | kW |
Rated Current | - | 19,00 | A |
Refrigerant / Charge / Eq. CO2 | - | R32 / 1,40 / 0,94 | type / kg / t |
Water pipes | Inlet | 5/4 | inch |
Water pipes | Outlet | 5/4 | inch |
Water temperature range | Heating | 25 ~ 65 | °C |
Water temperature range | Cooling | 5 ~ 25 | °C |
Water Pump | Max. Flow | 4,5 | m3 / h |
Water pump | Power input | 95 | W |
Water flow switch | Minimum flow | 0,4 | l / min |
Expansion tank | Volume | 8 | l |
Expansion tank | Maximum pressure | 3 | Bar |
Expansion tank | Precharged pressure | 1 | Bar |
Electric heater | Mode | automatic | |
Electric Heater | Steps | 1 | - |
Electric Heater | Capacity | 3,0 | kW |
Electric Heater | Combination | 3 | - |
Electric heater | Voltage / phase / frequency | 220–240 / 1 / 50 | V / f / Hz |
Heat Exchanger | Type | Brazed Plate HEX | - |
Heat Exchanger | Quantity | 1 | - |
Safety Valve | - | 3 | Bar |
Sound Pressure Level at 1 m | LpA | 49 | dB |
Dimension | (w x h x d) | 1385 × 865 × 526 | mm |
Package dimension | (w x h x d) | 1465 × 1035 × 560 | mm |
Net Weight | - | 105 | kg |
Gross Weight | - | 132 | kg |
Operating Temperature Range | Cooling | -5 ~ 43 | °C |
Operating Temperature Range | Heating | - 25 ~ 35 | °C |
Operating Temperature Range | Water heating | - 25 ~ 43 | °C |
Notes |
CAPACITIES AND POWER INPUTS ARE BASED ON THE FOLLOWING CONDITIONS:
The specifcation of products is subject to change based on further development of the units by the producer and can be changed without prior notice. Refer to rating label. |